What is a vertical loop system? |
|
A
vertical ground loop system may be installed in vertical bore holes 45
to 150m deep. Each hole contains a single loop of pipe. After the pipe is
inserted, the hole is backfilled. The number of loops required
depends on ground conditions, air conditioning and heating load and the
depth of each hole. This design is well suited for retrofit applications
where landscraping is already complete.
|
|
What is a horizontal loop system? |
|
A
horizontal ground loop system is usually selected when adequate space is
available and trenching can be easily accomplished. A series of parallel
pipes are laid out in trenches 0.9 to 1.8 m below the ground
surface.Then backfilled. Often multiple pipes are used to maximize the
heat transfer capability of each trench. The amount of pipe and the size
of the ground loop field is based on ground conditions, heating and
cooling requirement.
|
|
What is a water immersion loop system? |
|
An
application located near a lake or pond can benefit from a surface water
system. Many local building codes require a retention pond for rain run
off from large roof and parking area of new buildings. These retention
ponds can become low cost and efficient energy sources. Because of the
excellent thermal property of water, a loop may be submerged in a series
of coils beneath the water surface. |
|
How much do geothermal heat pumps cost?
All heat pumps are
available with a cooling option, please add £480.
|
|
|
Geothermal
heat pumps 8 to 15 KW |
Weight kg |
Price £ |
|
 |
GHP 8 KW
220V/50hz |
105 |
1480 |
|
GHP 10 KW
220V/50hz |
110 |
1820 |
|
GHP 13 KW
380V/50hz |
120 |
2100 |
|
GHP 15 KW
380V/50hz |
130 |
2280 |
|
|
Prices exclude delivery.
Prices include internal
hot water circulator pump.
Guarantee 2 years |
|
|
| |
|
Geothermal
heat pumps 20 to 30 KW |
Weight kg |
Price £ |
|
 |
GHP 20 KW
380V/50hz |
180 |
3200 |
|
GHP 26 KW
380V/50hz |
195 |
3370 |
|
GHP 30 KW
380V/50hz |
210 |
3900 |
|
|
|
|
|
| |
|
|
|
Heat pump technical specifications.


Which heat pump?
Most domestic reqirements
(average 3 bedroomed house) are easily covered by a 220v/50hz heat pump
offering 8 to 10 kw output.
Larger houses will need a
380v (3 phase) electrical supply to run a 13 to 20 kw heat pump
Commercial users please
contact us for heat pump technical specifications to suit your
requirement. |
|
|
Heat pump with cooling |
Type |
8KW |
10KW |
13KW |
15KW |
|
Dimensions,weights,connection dimensions |
|
Dimensions |
HxWxD |
1000x600X600 mm |
|
Weight |
kg |
105 |
110 |
120 |
130 |
|
Refrigerant |
Type |
R407C |
|
Filling weight |
kg |
2 |
2.3 |
2.5 |
2.8 |
|
Permissible operating pressure |
Mpa |
3 |
3 |
3 |
3 |
|
Pipe connector-hot side |
Inch |
G1" |
G1" |
G1" |
G1" |
|
Pipe connector-cold side |
Inch |
G1" |
G1" |
G1" |
G1" |
|
Evaporator |
Type |
Brazed plate heat exchanger |
|
Condenser |
Type |
Brazed plate heat exchanger |
|
Compressor |
|
ixScroll |
IxScroll |
IxScroll |
IxScroll |
|
Performance Heating |
|
Heat output |
at B0/W35(1) |
kW |
8 |
10.2 |
13.1 |
15.5 |
|
Power consumption |
kW |
1.9 |
2.36 |
2.95 |
3.53 |
|
Performance factor |
|
4.21 |
4.32 |
4.44 |
4.39 |
|
Heat output |
atW10/W35(2) |
kW |
10.1 |
12.9 |
16.7 |
19.6 |
|
Power consumption |
kW |
1.89 |
2.39 |
3.01 |
3.57 |
|
Performance factor |
|
5.34 |
5.4 |
5.55 |
5.49 |
|
Process medium |
|
Brine/water values in [ ] |
|
Process medium |
|
Brine made from water with 33Vol.% ethylene glycol |
|
Volume flow |
inside |
m3/h |
0.88[0.72] |
1.1 [0.9] |
1.4[1.2] |
1.7[1.4] |
outside |
m3/h |
2.1[1.8] |
2.6[2.2] |
3.4[3.1] |
4.1[3.7] |
|
Performance Cooing |
|
Cooing output |
at W20/W7(3) |
kW |
9.2 |
12 |
15 |
18 |
|
Power consumption |
kW |
1.65 |
2.1 |
2.6 |
3.2 |
|
Performance factor |
|
5.58 |
5.71 |
5.77 |
5.63 |
|
Volume flow |
inside |
m3/h |
1.58 |
2.1 |
2.58 |
3.1 |
outside |
m3/h |
2.1 |
2.6 |
3.4 |
4.1 |
|
Power |
Type |
Single phase |
Single phase |
Triple phase |
Triple phase |
|
Sound power level |
dB(A) |
46 |
47 |
48 |
48 |
(1)B0/W35=Brine water inlet temperature 0°C,heating flow
35°C
(2)W10/W35=Well water inlet temperature 10°C,heating flow
35°C (3)W20/W7=Outside water inlet temperature 20°C,cooling flow 7°C |
| |
|
|
|
Downloads
Click to download
Technical data sheet
Installation manual
Operation manual


Our heat pumps are
manufactured in China by the HISEER group, specialists in air
conditioning and refrigeration systems for many years. Designed to
European specification HISEER heat pumps feature componants supplied by
leading brand names, HITACHI compressors, WILO water pumps,
HONEYWELLmulti way valves and thermal relays by SCHNEIDER.
All products are
manufactured to current EEC, CE regulations, ISO 9001 standards, and
carry a two year guarantee. |
|
|
Heat pump with cooling |
Type |
20KW |
26KW |
30KW |
|
Dimensions,weights,connection dimensions |
|
Dimensions |
HxWxD |
1000x800X600 mm |
|
Weight |
kg |
180 |
195 |
210 |
|
Refrigerant |
Type |
R407C |
|
Filling weight |
kg |
4 |
4.5 |
5 |
|
Permissible operating pressure |
Mpa |
3 |
3 |
3 |
|
Pipe connector-hot side |
Inch |
G11/4" |
G11/4" |
G11/4" |
|
Pipe connector-cold side |
Inch |
G11/4" |
G11/4" |
G11/4" |
|
Evaporator |
Type |
Brazed plate heat exchanger |
|
Condenser |
Type |
Brazed plate heat exchanger |
|
Compressor |
|
2xScroll |
2xScroll |
2xScroll |
|
Performance Heat pump |
|
Heat output |
at B0/W35(1) |
kW |
20 |
26 |
30.5 |
|
Power consumption |
| |